KNX dimmer 90-230 Vac 1 channel

EK-GD2-TP-1-HV
ORDERING CODE EK-GD2-TP-1-HV DESCRIPTION KNX bus device with single-channel phase cut dimmer function for light loads, with supply voltage 90-230 Vac at 50/60 Hz. Use in KNX standard home and building automation systems. TECHNICAL DATA Inputs Power supply: 90 - 230 Vac 50/60 Hz Maximum input current: 1 A Outputs Power supply: 90 - 230 Vac 50/60 Hz Output power 110 W @ 110 Vac, 220 W @ 220 Vac, 230 W @ 230 Vac Minimum load power: 1 W Maximum output current: 1 A DIMMING Trailing edge dimming mode with open load control (OPEN CIRCUIT) and short circuit on the load (SHORT CIRCUIT) Dimming range: 1-100% NOTES Loads that can be used with the dimmer can be: incandescent lamps, mains voltage halogen lamps, mains voltage dimmable LED lamps, mains voltage dimmable LED strips, switching power supplies for dimmable LEDs in phase cut. The dimmer cuts phase in trailing edge mode. ENVIRONMENTAL CONDITIONS AND OTHER CHARACTERISTICS Operating temperature: - 20 ° C ... + 40 ° C Storage temperature: - 40 ° C ... + 60 ° C Transport temperature: - 40 ° C ... + 60 ° C Maximum case temperature (tc): 80 °C Relative humidity: 91% non-condensing Protection degree: IP00 Loads and supply wiring: 1.5 mm2 solid – 2.5 mm2 stranded (16 - 13 AWG) Max torque 0.5 Nm for screw terminals KNX bus wiring: 0.26 ÷ 0.5 mm2 – 23 ÷ 20 AWG Stripping: 5.0 - 6.0 mm Housing in plastic material Device suitable for installation in flush-mounting wall boxes Weight: 37 g Dimensions (LxHxW): 53 x 61 x 29 mm FUNCTIONAL CHARACTERISTICS - ON/OFF control and regulation of the luminous intensity of single or group lighting fixtures - Fade time on and off, minimum and maximum brightness level, linear or logarithmic regulation curve settable via ETS - Soft or instant on and off, with settable delay - Configuration of behavior after power recovery, bus ON/OFF, download via ETS - Block function, forced operation, staircase light, scenarios, night, counter and logic functions for each channel, settable via ETS - Alarm for short circuit, open load and power failure - Auxiliary output function with status advice via KNX - Installer mode (with KNX bus active): pressing the programming button for approximately 2 seconds activates/deactivates the flashing of the programming and load LED approximately every 1 s CONFIGURATION AND COMMISSIONING A detailed description of the parameters can be found in the application manual of the device. Configuration and commissioning require ETS5 or later versions. ETS application program: APEKGDXTPXHV##.knxprod (## = release). Available languages: English, French, German, Italian.
Category Value
Catalog Item Name KNX dimmer 1 CH 90-230 Vac
Application Program Name EK-GDX-TPX-HV
Order Number EK-GD2-TP-1-HV
Rail Mounted Yes
Manufacturer Website Ekinex S.p.A.